20 Nov 74
Symptom: DXF-19, DXH-19, MGC-19 – ERROR CODE P2
Solution: MULTIPLE SOLUTIONS
Cause: HIGH TEMPERATURE PROTECTION OF IPM MODULE
Remarks:
DESCRIPTION:
IF THE TEMPERATURE OF THE IPM MODULE IS HIGHER THAN SETTING VALUE, THE LED DISPLAYS THIS FAILURE CODE.
REPAIR:
1) CHECK THE FASTENING SCREWS ON THE PCB AND IPM RADIATOR:
ARE THEY FIXED TIGHTLY?
NO = TIGHTEN THE SCREWS AND APPLY SILICON GREASE
YES = REPLACE THE OUTDOOR CONTROL PCB
YES = REPLACE THE OUTDOOR CONTROL PCB