Symptom: DXG-18, DXH-18, MGC-18 – ERROR CODE U9

Solution: MULTIPLE SOLUTIONS

Cause: ZERO-CROSSING MALFUNCTION OF OUTDOOR UNIT

Remarks:

DESCRIPTION:

*AC UNIT IN COOLING/DRY MODE: THE COMPRESSOR STOPS OPERATING WHILE THE INDOOR FAN WILL CONTINUE TO OPERATE.

*AC UNIT IN HEATING MODE: THE COMPLETE UNIT STOPS OPERATION.

REPAIR:

1) THE SUPPLY VOLTAGE IS UNSTABLE:

SOLUTION 1) IF THE VOLTAGE IS NOT STABLE, PLEASE ADD A VOLTAGE REGULATOR

2) WRONG WIRING CONNECTION OF INDOOR UNIT:

SOLUTION 2) PLEASE RECONNECT THE WIRING OF THE INDOOR UNIT

3) THE PROTECTIVE TUBE IS MALFUNCTIONING:

SOLUTION 3) REPLACE IT WITH A NEW CORRESPONDING PROTECTIVE TUBE

4) THE TRANSFORMER IS MALFUNCTIONING:

SOLUTION 4) REPLACE IT WITH A NEW CORRESPONDING TRANSFORMER

5) THE PCB IS MALFUNCTIONING:

SOLUTION 5) REPLACE IT WITH A NEW CORRESPONDING OUTDOOR UNIT PCB