*AC UNIT IN COOLING/DRY MODE: THE COMPRESSOR STOPS OPERATING WHILE THE INDOOR FAN WILL CONTINUE TO OPERATE.
*AC UNIT IN HEATING MODE: THE COMPLETE UNIT STOPS OPERATION.
REPAIR:
1) THE SYSTEM IS NOT OK:
SOLUTION 1) CHECK IF THERE IS A LEAKAGE OF REFRIGERANT, IF AN EXPANSION VALVE IS BLOCKED, IF A CONDENSER OR EVAPORATOR IS DIRTY OR IF THE WORKING CONDITION IS BAD
2) THE COMPRESSOR HAS A DEFECT:
SOLUTION 2) CHECK IF THE COMPRESSOR HAS A DEFECT. REPLACE THE COMPRESSOR IF NEEDED
3) THE WIRING OF THE OVERLOAD SWITCH IS NOT OK:
SOLUTION 3) CHECK IF THE WIRING OF THE OVERLOAD SWITCH IS LOOSE OR PULLED OFF
4) DEFECT IN THE OVERLOAD PROTECTION CIRCUIT:
SOLUTION 4) CHECK IF THERE IS A DEFECT IN THE OVERLOAD PROTECTION CIRCUIT. UNDER NORMAL CIRCUMSTANCES, THE RESISTANCE BETWEEN BOTH ENDS OF TERMINAL IS LESS THAN 1 OHM
5) THE MALFUNCTION PROTECTOR IS BROKEN
SOLUTION 5) CHECK IS THE MALFUNCTION PROTECTOR IS BROKEN. IF YES, PLEASE REPLACE WITH A NEW CORRESPONDING PART
6) THE VOLTAGE IS TOO LOW:
SOLUTION 6) CHECK IF THE SYSTEM PRESSURE IS TOO LOW. IF YES, PLEASE ADJUST IT