40

Symptom: DXG-18, DXH-18, MGC-18 – ERROR CODE H2

Solution: MULTIPLE SOLUTIONS

Cause: STATIC DEDUSTING PROTECTION

Remarks:

REPAIR:

1) THE WIRING OF THE DUST CATCHER IS NOT OK:

SOLUTION 1) CHECK IF THE WIRING OF THE DUST CATCHER IS WELL CONNECTED OR NOT. RECONNECT IF NEEDED

2) THE DUST CATCHER IS DIRTY:

SOLUTION 2) REMOVE THE DIRT OF THE DUST CATCHER

3) THE DUST CATCHER IS BROKEN:

SOLUTION 3) REPLACE WITH A NEW CORRESPONDING DUST CATCHER

4) THE PCB IS BROKEN:

SOLUTION 4) REPLACE WITH A NEW CORRESPONDING PCB