*AC UNIT IN COOLING/DRY MODE: THE COMPRESSOR STOPS OPERATING WHILE THE INDOOR FAN WILL CONTINUE TO OPERATE.
*AC UNIT IN HEATING MODE: THE COMPLETE UNIT STOPS OPERATION.
REPAIR:
1) THE WIRING OF THE COMPRESSOR IS NOT OK:
SOLUTION 1) PLEASE CHECK IF THE WIRING OF THE COMPRESSOR IS CONNECTED CORRECTLY, OR THE ELECTRIC BOX AND COMPRESSOR HAVE A MISMATCH
2) SOMEONE TURNS OFF THE UNIT AND THEN TURNS THE UNIT BACK ON BEFORE THE COMPRESSOR STOPPED FOR 3 MINUTES:
SOLUTION 2) CHECK IF THE STOP DURATION OF THE COMPRESSOR IS LONGER THAN 3 MINUTES
3) THE VOLTAGE IS TOO LOW:
SOLUTION 3) CHECK IF THE SYSTEM PRESSURE IS TOO LOW. IF YES, PLEASE ADJUST IT
4) OVERLOAD PROTECTION IS ABNORMAL:
SOLUTION 4) CHECK IF THE PROTECTION UNDER OVERLOAD IS OK OR NOT
5) SYSTEM IS ABNORMAL:
SOLUTION 5) CHECK IF THERE IS EXCESSIVE REFRIGERANT, A PIPELINE IS BLOCKED OR THERE IS A DIRTY CONDENSER OR EVAPORATOR
6) DEFECT OF OUTDOOR UNIT CONTROLLER:
SOLUTION 6) REPLACE WITH A NEW CORRESPONDING PCB
7) DEFECT OF THE COMPRESSOR:
SOLUTION 7) REPLACE WITH A NEW CORRESPONDING COMPRESSOR